Chlorine Gas Leak Absorption
- Minimum Order Quantity
- 10 Set
- Price Range
- 35000.00 - 70000.00 INR/Set
Chlorine Gas Leak Absorption System with Neutralization
For our valued clients, we have bring forth a quality assortment of Chlorine Gas Leak Absorption System with Neutralization. We, at our end make sure that our entire range of leak absorption system automatically controls the leakage of chlorine. This Chlorine Gas Leak Absorption System with Neutralization is extensively used as a safety device used to reduce the diffusion of chlorine gas into atmosphere. Our offered gas leak absorption system is also used as a cleaning agent and is offered to the clients at nominal prices.
Further Details
This system automatically controls the leakage of chlorine from 100kg and 900kg tonnels and that chlorine is used as a cleaning agent. This system consists of blower, absorption tower with Raschig rings, alkali tank (NaOH) etc. It makes a person to take breath easily. It has the absorption capacity of 100kg/hr and 200kg/hr for 100kg and 900kg cylinders. There are two kinds of absorption systems like:
- Tower Type.
- Pit Type.
The Chlorine gas leakage absorption system
Basic system consists of
- Casutic solution holding tank
- Caustic recirculating pump.
- FRP scrubber with palrings.
- FRP chimney for air vent.
- Suction blower with motor
- FRP ducting.
- Toner/ cylinder hood.
- Connical Hood.
- Flexible PVC piping
Method of operation
Manual Mode
- If leakage of chlorine gas sensed by means of ammonia torch and the leakage is uncontrollable or to remove the excess of chlorine gas in the chlorination room.
- Preparation of caustic solution in caustic holding tank should be kept ready.
- Wear Self breathing apparatus if the caustic recirculation pump and blower starters are in the same chlorination room.
- Start the blower so that the blower will suck the chlorine gas in the room/ atmosphere and put it in the scrubbing system.
- Also start the caustic solution recirculation pump so that the chlorine gas trapped in the scrubbing system is absorbed in the caustic solution and accumulated in caustic holding tank as hypo chlorine. There hypo chlorine solution can be reused as disinfectant or can be used as cleaning agent so that the leaked chlorine gas can be used with out wastage
Note : Never mix caustic flakes with water inside the caustic holding tank for the preparation of caustic solution. It should be prepared outside or use caustic solution which is readily available.
Automatic Mode
In addition to the basic absorption system, it consists of
- Leakage Detector.
- Leakage Sensors.
- Leakage Alarm device.
- Control panel.
Method of Operation:
As soon as the leakage of chlorine is sensed by the sensor, the alarm device beeps and it automatically operates the FRP Blower and Caustic recirculation Pump with the help of control panel and neutralizes the chlorine gas.
Features:
- No trained Person required for operation of the system.
- The automatic system can also run in manual mode.
- The whole system is totally closed.
- RCC Pit with FRP lining for Caustic solution holding tank.
- Suction blower with motor
- FRP ducting.
- Toner/cylinder hood.
- Connical Hood.
- Flexible PVC piping
- Manual Mode
- Automatic Mode
- If leakage of chlorine gas is sensed by means of ammonia torch and the leakage is uncontrollable or to remove the excess of chlorine gas in the chlorination room.
- Preparation of caustic solution in RCC Pit with FRP Lining for Caustic solution holding tank.in caustic holding tank should be kept ready.
- Wear Self breathing apparatus if the blower starters are in the same chlorination room.
- Start the blower so that the blower will suck the chlorine gas in the room/ atmosphere and put it in the bottom of the Pit which is filled with caustic solution. The chlorine .gas is absorbed in the caustic solution and accumulated in caustic holding tank as hypo chlorine.
- The hypo chlorine solution can be reused as disinfectant or can be used as cleaning agent so that the leaked chlorine gas can be used without wastage
In addition to the basic absorption system, it consists of
- Leakage Detector.
- Leakage Sensors.
- Leakage Alarm device.
- Control panel.
As soon as the leakage of chlorine is sensed by the sensor, the alarm device beeps and it automatically operates the FRP Blower with the help of control panel and neutralizes the chlorine gas.
Feature:
- Specially trained Person required for operation of the system.
- The automatic system can also run in manual mode.
- The whole system is totally Open as it contains alkaline solution.
Specification
Usage/Application | Industrial |
Brand | SM Polymers |
Model Name/Number | As per model |
Color | Standard |
Body Material | MS |
Cylinder Capacity | 900 Kgs. |
- FOB Port
- Maharashtra, India
- Supply Ability
- 20 Set Per Week
- Delivery Time
- 30 Days
- Sample Available
- Yes
- Sample Policy
- Contact us for information regarding our sample policy
- Packaging Details
- Standard Packaging
- Main Domestic Market
- All India
- Certifications
- ISO 9001:2008